Hi,
Does anybody know how to reset the error 093-314? What NVM number to reset? It´s a Xerox Docucolor 250! Please help!
Thanks
ewalker

Post time: 2010-12-5 19:19:31 |Show all posts
You will need to check the dispense motor and the cartridge motor, if not working then replace it. then you can reset the NVM as mentioned above

Post time: 2010-11-21 12:23:24 |Show all posts
I have seen the 'spring' that cleans the low toner sensor get pulled out of the toner supply unit and cause these codes to repeat. Toner gets caked on the sensor making the copier think it's full only to have the developer density go light.
If it repeats, you are due for a new toner supply unit. The spring ain't spared.

Post time: 2010-11-7 05:27:17 |Show all posts
REALLY REALLY THANKS! tomorrow I´ll try!

Post time: 2010-10-23 22:31:10 |Show all posts
762-312 to 0

Post time: 2010-10-9 15:35:03 |Show all posts
After I check the yellow dispense motor and yellow low toner sensor do you think I have to reset something?

Post time: 2010-9-25 08:38:56 |Show all posts
Some times I have the same problem with the magenta dispenser (093-315) and I have to reset a NVM code to reset the problem...

Post time: 2010-9-11 01:42:49 |Show all posts
it is yellow toner dispense fault.
you have to check yellow dispense motor and yellow low toner sensor