Service code xpe-09-43001

[Copy link]

Post time: 2013-4-27 19:28:28 |Show all posts
dc 951 will not run due to this error charge 1 (m) pr residual voltage. All other jobs will run just not the xerographics  any ideas would be greatly appreciated. charge station on unit 1 has all new wires and grid.

Post time: 2013-4-28 07:14:29 |Show all posts
oh man, Im sorry I didnt get to this thread sooner....  

same exact problem here last spring. little plastic tensioner, that holds grid tight, broke on one side. held it in with rubber bands until I could get a new little clip....

Post time: 2013-4-28 05:35:08 |Show all posts
thank you for the help I got it was just a bow in the pre-transfer grid

Post time: 2013-4-28 04:30:21 |Show all posts
Thanks. I haven't gotten deep in an Igen 4 yet. I will soon though.

Post time: 2013-4-28 02:38:10 |Show all posts
I presume you mean the pots on the amp by the toner hoppers?  If so that is iGen3 only.  iGen4's use 2060 ESV's and the amp is on the dev tank which is not reliably field adj

--
Mark

Post time: 2013-4-28 00:51:08 |Show all posts
You can also do a voltage adjustment on the ESV on the faulty station. Need the edoc to adjust it properly. Not to hard to do. The voltage gets out of whack sometimes and you have to adjust the variable resistor for the faulty station. I've had to do this sometimes.

Post time: 2013-4-27 23:30:08 |Show all posts
Could be anything from a faulty esv to the cleaner not cleaning.  Things to check

1 - Cleaner is cleaning OK.  Brushes OK, Flicker bars not built up with compacted toner.  Cleaner vacuums Good (3.5 inches of water)
2 - All grid shields (inboard and outboard) are still in place on all stations inc Pre - transfer
3 - All grids are good and none bent
4 - all charge corotrons are seated fully and the connectors are secure at the rear
5 - Faulty ESV - Service rep is needed to check readings and replace

This fault can sometimes be declared on one station, but the root cause can be occurring on a different station.

--
Mark

Post time: 2013-4-27 21:59:40 |Show all posts
Igen 4

Post time: 2013-4-27 20:53:05 |Show all posts
Are you running an iGen3 or 4?

--
Mark
You have to log in before you can reply Login | register